Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters

Database
Language
Document Type
Year range
1.
J Clin Virol ; 141: 104906, 2021 Aug.
Article in English | MEDLINE | ID: covidwho-1300869

ABSTRACT

OBJECTIVES: The emerging SARS-CoV-2 variants of concern (VoC), B.1.1.7, B.1.351 and P.1, with increased transmission and/or immune evasion, emphasise the need for broad and rapid variant monitoring. Our high-volume laboratory introduced a PCR variant assay (Variant PCR) in January 2021 based on the protocol by Vogels et al. STUDY DESIGN: To assess whether Variant PCR could be used for rapid B.1.1.7, B.1.351 and P.1 screening, all positive SARS-CoV-2 airway samples were prospectively tested in parallel using both the Variant PCR and whole genome sequencing (WGS). RESULTS: In total 1,642 SARS-CoV-2 positive samples from individual patients were tested within a time span of 4 weeks. For all samples with valid results from both Variant PCR and WGS, no VoC was missed by Variant PCR (totalling 399 VoC detected). Conversely, all of the samples identified as "other lineages" (i.e., "non-VoC lineages") by the Variant PCR, were confirmed by WGS. CONCLUSIONS: The Variant PCR based on the protocol by Vogels et al., is an effective method for rapid screening for VoC, applicable for most diagnostic laboratories within a pandemic setting. WGS is still required to confirm the identity of certain variants and for continuous surveillance of emerging VoC.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , Laboratories , Polymerase Chain Reaction , Whole Genome Sequencing
2.
J Clin Virol ; 137: 104789, 2021 04.
Article in English | MEDLINE | ID: covidwho-1126918

ABSTRACT

BACKGROUND: Rapid antigen tests (RATs) may be included in national strategies for handling the SARS-CoV-2 pandemic, as they provide test results rapidly, are easily performed outside laboratories, and enable immediate contract tracing. However, before implementation further clinical evaluation of test sensitivity is warranted. OBJECTIVES: To examine the performance of Abbott's Panbio™ COVID-19 Ag Rapid Test Device for SARS-CoV-2 testing in a low to medium prevalence setting in Norway. STUDY DESIGN: A prospective study comparing the results of the Panbio RAT with PCR in 4857 parallel samples collected at a SARS-CoV-2 test station in Oslo, and from COVID-19 outbreaks in six Norwegian municipalities. RESULTS: A total of 4857 cases were included in the study; 3991 and 866 cases from the test station and the outbreak municipalities, respectively. The prevalence at the test station in Oslo was 6.3 %, and the overall sensitivity of the RAT was 74 %. Increased sensitivity was observed in patients who experienced symptoms (79 %) and when considering samples with viral loads above estimated level of infectivity (84 %), while it was lower in asymptomatic persons (55 %). In the outbreak municipalities, the overall prevalence was 6.9 %, and the total sensitivity of the RAT was 70 %. CONCLUSIONS: Our results indicate that the test correctly identified most infectious individuals. Nevertheless, the sensitivity is considerably lower than for PCR, and it is important that the limitations of the test are kept in mind in the follow-up of tested individuals.


Subject(s)
Antigens, Viral/analysis , COVID-19 Serological Testing/methods , COVID-19/diagnosis , COVID-19/virology , SARS-CoV-2/isolation & purification , COVID-19/epidemiology , COVID-19/immunology , COVID-19 Testing/methods , False Negative Reactions , False Positive Reactions , Humans , Norway/epidemiology , Prospective Studies , SARS-CoV-2/immunology , Sensitivity and Specificity , Viral Load
SELECTION OF CITATIONS
SEARCH DETAIL